Definitions #
The EU law that sets strict safety and performance rules for tests performed on samples like blood or tissue, including COVID and blood-screening tests.
Technical Regulation (EU) 2017/746 governing the placing on the market and putting into service of in vitro diagnostic medical devices, replacing Directive 98/79/EC.
Example Under IVDR, the manufacturer must submit a performance evaluation report and engage a notified body for higher-risk IVDs.
Etymology #
From Latin in vitro (in glass), diagnostic, and regulation; the title of Regulation (EU) 2017/746 adopted by the European Parliament and Council.
Collocations #
- notified body A designated conformity assessment body that audits and certifies higher-risk IVDs under IVDR.
- conformity assessment The procedure demonstrating that a device meets IVDR requirements before CE marking.
- CE marking The marking affixed to show an IVD complies with applicable EU legislation.
- performance evaluation The continuous assessment and analysis of data to establish or verify the scientific validity and performance of a device.
Real Business Examples #
- Under IVDR, the manufacturer must submit a performance evaluation report and engage a notified body for class D IVDs.
- The legacy IVD could no longer be placed on the EU market once the IVDR transition deadline expired without a valid certificate.
- Regulatory affairs updated the technical documentation to align with the new IVDR common specifications.
Register & Variants #
- Register: formal
- BrE/AmE: Used across EU/EEA member states; the abbreviation IVDR is the standard term in global regulatory English.
Synonyms & Antonyms #
- Synonyms: IVD Regulation, Regulation (EU) 2017/746
Common Errors #
- Assuming a certificate under the old IVDD remains valid indefinitely. IVD Directive certificates only remain valid during the IVDR transition conditions, subject to timelines and no significant device changes.
- Treating laboratory-developed tests used within a single health institution as automatically exempt. In-house devices are subject to specific conditions in Article 5(5), including equivalent safety and performance requirements.
Confusable Terms #
- IVDD vs In Vitro Diagnostic Regulation
- The IVD Directive 98/79/EC was the predecessor framework; IVDR is the current directly applicable regulation with broader classification and stricter evidence.
- MDR vs In Vitro Diagnostic Regulation
- The Medical Devices Regulation covers most medical devices, whereas IVDR covers in vitro diagnostic products specifically.
Frequently Asked Questions
Does IVDR require a notified body for every IVD?
No. Lower-risk devices may be self-certified, but higher classes typically require notified-body conformity assessment.
What is the UDI under IVDR?
The Unique Device Identification system enables traceability of devices through the supply chain and incident reporting.