Medical Devices · Reference Entry

Unique Device Identification

Unique Device Identifications (pl., rare)

//juːˈniːk dɪˈvaɪs aɪˌdɛntɪfɪˈkeɪʃən//
//juˈnik dɪˈvaɪs aɪˌdɛntəfɪˈkeɪʃən//
phrase Medical Devices u-NIQUE-de-VICE-i-DEN-ti-fi-CA-tion Also: UDI · UDI-DI · UDI-PI

A standard code put on medical device labels and packages so a specific device model and production batch can be traced.

Published 2026-10-25 Category: Medical Devices Reviewed by Alex Grant, Editor-in-Chief
On this page
Advertisement
Advertisementdisplay · responsive
01

Definitions #

A standard code put on medical device labels and packages so a specific device model and production batch can be traced.

Technical An FDA/EU system using a UDI-DI device identifier and UDI-PI production identifier, marked on the label and submitted to GUDID/EUDAMED.

Example The implant's UDI was recorded in the patient's operative record before the recall notice was issued.

The number regulators and hospitals use to identify and pull back a particular device when a safety problem is found.

Technical A standardized traceability mechanism supporting adverse-event reporting, field safety corrective actions, and post-market surveillance.

Example Investigators used the UDI-PI, including lot and expiry, to scope the recall to affected sterile batches.

02

Etymology #

Mandated under the US FDA Amendments Act of 2007 and phased in from 2014; the term combines unique, device, and identification to distinguish individual device models and production units.

03

Collocations #

  • UDI-DI (Device Identifier) The device identifier, which points to the device record in GUDID.
  • UDI-PI (Production Identifier) The production identifier: lot, serial number, manufacture date, or expiry.
  • UDI carrier The barcode or matrix code carrying the UDI on the label.
  • GUDID submission Filing the device record with the FDA database.
  • direct marking Permanent marking of the UDI on a reusable device.
  • issuing agency An accredited agency such as GS1 or HIBCC.
04

Real Business Examples #

  1. The implant's UDI was recorded in the patient's operative record before the recall notice was issued.
  2. Class III devices must bear a UDI on the label, and the DI must be registered in GUDID before commercial distribution.
  3. Investigators used the UDI-PI, including lot and expiry, to scope the recall to affected sterile batches.
Advertisement
Advertisementin-article · fluid
05

Register & Variants #

  • Register: formal
  • BrE/AmE: Used worldwide; the database differs by jurisdiction (GUDID in the US, EUDAMED in the EU).
06

Synonyms & Antonyms #

  • Synonyms: UDI, device UDI
07

Common Errors #

  • Treating UDI as a single serial number for every individual unit. UDI normally combines a fixed UDI-DI for the model with a UDI-PI such as lot or serial; the serial element is not always required by risk class.
  • Printing a barcode without submitting the DI record to GUDID/EUDAMED. Label marking and database registration are separate obligations; both must be completed where applicable.
  • Assuming low-risk Class I devices are exempt in all regions. Exemptions and compliance dates differ by jurisdiction and risk class, so verify current FDA and EU MDR timelines.
08

Confusable Terms #

GTIN vs Unique Device Identification
GTIN is a GS1 product number that may serve as the UDI-DI; UDI is the broader regulatory concept and also includes the PI.
Serial number vs Unique Device Identification
A serial number is only one possible UDI-PI element; UDI may instead use lot, manufacture date, or expiry depending on the device.
09

Frequently Asked Questions

What is the difference between UDI-DI and UDI-PI?

UDI-DI identifies the device model and is linked to the regulatory database record; UDI-PI identifies production data such as lot, serial, manufacture date, or expiry.

Does UDI appear directly on the device or only the box?

Usually on the label/package; reusable devices requiring reprocessing generally also need direct marking on the device itself.

Can UDI help during a recall?

Yes. It lets manufacturers, hospitals, and regulators identify the exact model and affected batches or units quickly.

Advertisement
Advertisementmultiplex · grid

Published: 2026-10-25 Category: Medical Devices