Definitions #
A standard code put on medical device labels and packages so a specific device model and production batch can be traced.
Technical An FDA/EU system using a UDI-DI device identifier and UDI-PI production identifier, marked on the label and submitted to GUDID/EUDAMED.
Example The implant's UDI was recorded in the patient's operative record before the recall notice was issued.
The number regulators and hospitals use to identify and pull back a particular device when a safety problem is found.
Technical A standardized traceability mechanism supporting adverse-event reporting, field safety corrective actions, and post-market surveillance.
Example Investigators used the UDI-PI, including lot and expiry, to scope the recall to affected sterile batches.
Etymology #
Mandated under the US FDA Amendments Act of 2007 and phased in from 2014; the term combines unique, device, and identification to distinguish individual device models and production units.
Collocations #
- UDI-DI (Device Identifier) The device identifier, which points to the device record in GUDID.
- UDI-PI (Production Identifier) The production identifier: lot, serial number, manufacture date, or expiry.
- UDI carrier The barcode or matrix code carrying the UDI on the label.
- GUDID submission Filing the device record with the FDA database.
- direct marking Permanent marking of the UDI on a reusable device.
- issuing agency An accredited agency such as GS1 or HIBCC.
Real Business Examples #
- The implant's UDI was recorded in the patient's operative record before the recall notice was issued.
- Class III devices must bear a UDI on the label, and the DI must be registered in GUDID before commercial distribution.
- Investigators used the UDI-PI, including lot and expiry, to scope the recall to affected sterile batches.
Register & Variants #
- Register: formal
- BrE/AmE: Used worldwide; the database differs by jurisdiction (GUDID in the US, EUDAMED in the EU).
Synonyms & Antonyms #
- Synonyms: UDI, device UDI
Common Errors #
- Treating UDI as a single serial number for every individual unit. UDI normally combines a fixed UDI-DI for the model with a UDI-PI such as lot or serial; the serial element is not always required by risk class.
- Printing a barcode without submitting the DI record to GUDID/EUDAMED. Label marking and database registration are separate obligations; both must be completed where applicable.
- Assuming low-risk Class I devices are exempt in all regions. Exemptions and compliance dates differ by jurisdiction and risk class, so verify current FDA and EU MDR timelines.
Confusable Terms #
- GTIN vs Unique Device Identification
- GTIN is a GS1 product number that may serve as the UDI-DI; UDI is the broader regulatory concept and also includes the PI.
- Serial number vs Unique Device Identification
- A serial number is only one possible UDI-PI element; UDI may instead use lot, manufacture date, or expiry depending on the device.
Frequently Asked Questions
What is the difference between UDI-DI and UDI-PI?
UDI-DI identifies the device model and is linked to the regulatory database record; UDI-PI identifies production data such as lot, serial, manufacture date, or expiry.
Does UDI appear directly on the device or only the box?
Usually on the label/package; reusable devices requiring reprocessing generally also need direct marking on the device itself.
Can UDI help during a recall?
Yes. It lets manufacturers, hospitals, and regulators identify the exact model and affected batches or units quickly.
Published: 2026-10-25 Category: Medical Devices