Definitions #
The process by which medical-device makers tell regulators about serious incidents, field-safety actions, and trends that could harm patients or users.
Technical The systematic collection, assessment, and submission of serious-incident reports and field-safety corrective actions to competent authorities under medical-device vigilance systems such as EU MDR.
Example The manufacturer completed vigilance reporting of the pump malfunction to the competent authority within the required 15-day timeframe.
Etymology #
Vigilance derives from Latin vigilantia (watchfulness); reporting refers to the formal notification act; combined in EU medical-device regulation to denote post-market surveillance reporting.
Collocations #
- serious incident report A mandatory report of an event that caused or could cause death or serious deterioration in health.
- field safety corrective action (FSCA) A manufacturer action, such as recall or software update, taken to reduce a risk of a device already on the market.
- trend reporting Statistical or periodic reporting of increases in expected or non-serious incidents defined in the post-market surveillance plan.
- vigilance system The documented procedures and responsibilities a manufacturer uses to collect, assess, and report device incidents.
Real Business Examples #
- Under EU MDR Article 87, vigilance reporting of the serious incident was submitted within 15 days of the manufacturer becoming aware.
- The quality team logged the complaint in the vigilance system and determined it met the threshold for MDR reporting.
- The FSCA notice was filed together with the vigilance report so the authority could review the recall rationale and timeline.
Register & Variants #
- Register: formal
- BrE/AmE: Global regulatory term; vigilance reporting and MDR reporting are predominantly used in the EU and UK, while the US FDA uses medical device reporting (MDR).
Synonyms & Antonyms #
- Synonyms: MDR reporting, medical device vigilance, incident reporting
Common Errors #
- Treating all customer complaints as vigilance-reportable events Only incidents meeting the serious-incident threshold, or FSCAs and reportable trends, are submitted; routine complaints remain in the complaint-handling and PMS files.
- Starting the reporting clock from the date of investigation closure The deadline generally runs from awareness of a reportable event, so late investigation cannot justify missing the statutory timeframe.
Confusable Terms #
- post-market surveillance (PMS) vs Vigilance Reporting
- PMS is the broader, ongoing data-collection and monitoring system; vigilance reporting is the subset that covers mandatory serious-incident and FSCA notifications.
- FDA Medical Device Reporting (MDR) vs Vigilance Reporting
- US FDA MDR is the parallel US reporting regime under 21 CFR 803; EU MDR vigilance reporting follows EU MDR Articles 87–92 and uses different forms and timelines.
Frequently Asked Questions
What is the standard reporting deadline for a serious incident in the EU?
Under EU MDR, serious incidents are generally reported within 15 days, serious public health threats within 2 days, and deaths or unforeseen serious deterioration within 10 days, subject to assessment.
Is vigilance reporting the same as MDR reporting?
They overlap but are not identical. MDR reporting commonly refers to EU MDR vigilance submissions, while FDA MDR is a separate US regime with its own rules and forms.
Do distributors have vigilance-reporting duties?
Yes. Distributors and importers must forward complaints and incident information to the manufacturer and, where applicable, notify the competent authority according to local rules.
Does a device recall always require a vigilance report?
A recall that qualifies as a field safety corrective action is normally reportable, together with a field safety notice; purely commercial stock returns without a safety rationale usually are not.
Published: 2026-11-09 Category: Medical Devices